the bodies: (812) 324-56-27, e-mail:
The main thing is the order of catalog the certification of the news To c[tat] by dealer the order of instrument contacts all goods the instruments
1 [u].[e]. = of 1 USD before the rubles on the course TsB RF on the day of payment.    
Search
Basket
Catalog
Calibrator of current and voltage 7016

Instrument unites before itself the functions of the multimeter of that making it possible to conduct the measurements of current and voltage, calibrator of equipment and generator, which can manufacture the signals of current and voltage, wide range for checking of electric diagrams, electric brushes and equipment.

  • Generation of pulses, the pulse measurements
  • Generation of direct current from 0 to ± 25 mA
  • Generation of constant stress from 0 to ± 15 [v]
  • Function of the measurement of the temperature

Specification

Functions of generator and the accuracy Constant stress From 0 to ± 1.5 [v], with the permission of 100 μ[V],
From 0 to ± 15 [v], with the permission 1 mV,
Reduction/the increase: ± 25 [m]A,
± 0.03% of the installation ± of 3 [e].[m].[r].
Direct current From 0 to ± 25 [m]A, with the permission of 1 μA,
Reduction/the increase: ± 12 before, ± 0.03% of the installation ± of 5 [e].[m].[r].
Generation of the pulse signal: From 0.5 to 4800 Hz, 28 ranges, ± 0.005% of the installation ± of 0.01 Hz.
Measured values and the basic accuracy Stress DC: From 50 mV to 250 beside, 5 ranges, ± 0.03% of chg of [velich]. ± 5 [e].[m].[r].
Stress is THE ACE: From 50 mV to 250 beside, 5 ranges, ± 0.7% of chg of [velich]. ± 20 [e].[m].[r].
Stress [AS]+DC: From 50 mV to 250 beside, 5 ranges, ± 0.8% of chg of [velich]. ± 25 [e].[m].[r].
Current DC: From 50 to 500 mA, 2 ranges, ± 0.03% of chg of [velich]. ± 5 [e].[m].[r].
Current AC: From 50 to 500 mA, 2 ranges, ± 0.6% of chg of [velich]. ± 20 [e].[m].[r].
Current AC+DC: From 50 to 500 mA, 2 ranges, ± 0.7% of chg of [velich]. ± 40 [e].[m].[r].
Resistance: From 500 Ohm to 50 M, 6 ranges, ± 0.15% of chg of [velich]. ± 5 [e].[m].[r].
Checking diode and electrical conductivity: It is possible
Temperature: From -40 to 1372 °C, ± 0.3% of chg of [velich]. ± 3 °C
(thermocouple K of the type, the measurement of temperature is possible before Fahrenheits °F)
Frequency: From 100 Hz to 200 kHz, 5 ranges, ± 0.02% of chg of [velich]. ± 3 [e].[m].[r].
Display [ZHKD], with the illumination, swing. induced number 51000.
Power source 1.5 [v] AA of alkaline (LR6) of battery × 8, either 1.2 [v] Ni -MH of battery × 8, or ACE is adapter.
Sizes and the mass 192 mm altitudes × of 90 mm latitude × 54 mm of thicknesses. Mass: 735 deg.
Accessories Bag for the transfer (1), ACE is adapter (1), Ni -MH battery (8), 3851-10 two verifying probes (1), clamps (1), yellow verifying probe (1), two verifying probes (1)

Options
3851-10 two verifying probes
3856-01 packets of connection (RS-232)
3856-02 packet of connection (USB)
9472 temperature sensors (class 1)
9473 temperature sensors (class 1)
9474 temperature sensors (class 1)
9475 temperature sensor (class 1)
9476 temperature sensor (class 1)





Current page: Calibrator of current and voltage Of hioki 7016
Calibrator of current and voltage Of hioki 7016
Home Sitemap Contact us

Most powerful site:
Files Downloads , motorcycle patches , reviews.great-car.co.uk , bauunternehmen polen , Used cars , food supplements