Multifunctional tester for measuring the parameters of safety one- and three phase networks SIRIUS 89

SIRIUS 89- is this complex multifunctional tester for fulfilling the measurements of the parameters of safety according to standards CEI 64-8/6 and VDE 0413, measuring the environmental parameters and analysis of the quality of the electric power of single-phase and three-phase networks. This instrument has very high resolution with the measurement of the impedance of chains and tire (F- F, F- N, F- Z) - 0.1[m] with the use of an option IMP57.

Basic functions

  • checking the integrity of shielding wires with 200mA
  • the measurement of insulation resistance with the DC voltage of 50/100/250/500/1000[V]
  • the measurement BONDS general and selective type parameters
  • the measurement of the impedance of grounding and in TT systems without turning off OF THE BONDS
  • the measurement of the impedance of chains and tire (F- F, F- N, F- Z) the calculation of the expected current [KZ]
  • the measurement of the ground resistance with the add. by the pintles of volts - by ampere method
  • the measurement of the specific resistance of ground
  • the measurement of the current of leakage (with the option HT96U)
  • the determination of phase sequence
  • the measurement of the frequency
  • measurement and the record of active, reactive and total power, active and reactive energy, and also coefficient THD
  • measurement, record and the analysis of the harmonics of voltage and current
  • the determination of the anomalies of stress - failures and of overvoltages - and the record of the results
  • selection of 5 assigned parameters for the record of the parameters
  • illumination measurement and the record of results (with the option HT53/05)
  • the measurement of temperature and humidity and the record of results (with the option HT52/05)
  • the sound-level measurement of dBA type 1 with the calculation of acoustic radiation pressure and the record of result (with the option HT55)
  • the built-in interface RS 232

Specification

Measurement of electrical conductivity (integrity) of shielding wires (regime Of auto, TRimer+, RTimer-)

Range, W

Permission, W

Accuracy

0,01 - 9,99

0,01

± 2%[IV] + of 2 unit of mf

10,0 - 99,9

0,1

Max. the stress of the test of 4[V] of ≤ V0 of ≤ of 24[V]
Test current to 200 mA constant with R of ≤ 13W, permission 1 mA

Measurement of insulation resistance

Test stress, before

Range, [M]W

Permission, [M]W

Accuracy

50

0,01 - 9,99

0,01

±2%[IV] of +2 unit of mf, V/R>1mA

10,0 - 49,9

0,1

50,0 - 99,9

0,1

±5%[IV] of +2 unit of mf, V/R≤1mA

100

0,01 - 9,99

0,01

±2%[IV] of +2 unit of mf, V/R>1mA

10,0 - 49,9

0,1

100,0 - 199,9

0,1

±5%[IV] of +2 unit of mf, V/R≤1mA

250

0,01 - 9,99

0,01

±2%[IV] of +2 unit of mf, V/R>1mA

10,0 - 49,9

0,1

200,0 - 249,0

1

250 - 499

1

±5%[IV] of +2 unit of mf, V/R≤1mA

500

0,01 - 9,99

0,01

±2%[IV] of +2 unit of mf, V/R>1mA

10,0 - 49,9

0,1

200,0 - 499,0

1

500 - 999

1

±5%[IV] of +2 unit of mf, V/R≤1mA

1000

0,01 - 9,99

0,01

±2%[IV] of +2 unit of mf, V/R>1mA

10,0 - 49,9

0,1

200,0 - 999,0

1

1000 - 1999

1

±5%[IV] of +2 unit of mf, V/R≤1mA

Max test stress 1,3 * the rating
Current [KZ] < of 6.0 mA with 500 [v]
Rating of the test current > of 2,17 mA with 500[V] and 230[k]W of load and >1[mA] with the remaining conditions

Checking the tripping time OF THE BONDS

Test current 10/30/100/300/500 mA
Type is BONDS ACE, A general and selective
Stress is phase/earth 100 - 255[V], 50 Hz

Range, ms

Permission, ms

Accuracy

½ IΔN, IΔN 0 - 999
2IΔN is 0 - is 200 is general
0 - 250 selective
5IΔN BONDS 0 - 50 general
0 - 160 selective

1

±2%[IV] of +2 unit of mf

Contact voltage Of u[p]

Stress, before

Permission, before

Accuracy

0 - 2 * U[p] (Of u[p] from 25 [v] to 50 c)

0,1

-0%, + 2%[IV] of +2 unit of mf

Measurement of the impedance of grounding without turning off OF THE BONDS

Range, W

Permission, W

Accuracy IΔN

1 1999

1

-0%, + 5%[IV] of +2 unit of mf

Test current 0,5 IΔN for the test Of u[p], 15[mA] for Ra of 15[mA] test


Checking the differential current of turning off OF THE BONDS

Type OF THE BONDS

Range IΔN, mA

Permission, mA

Accuracy IΔN

With IΔN of ≤ 10 mA

ACE

(0,5 - 1,4) *IΔN

0,1*IΔN

-0%, + 5% OF IΔN

A

(0,5 - 2,4) *IΔN

0,1*IΔN

-0%, + 5% OF IΔN

With IΔN of >10 mA

ACE

(0,5 - 1,4) *IΔN

0,1*IDN

-0%, + 5% OF IΔN

A

(0,5 - 2)*IΔN

0,1*IΔN

-0%, + 5% OF IΔN


Frequency (current loop and measurement BY BONDS actively only with 50[Gts])

Range, Hz

Permission, Hz

Accuracy

47,0 - 63,6

0,1

±1%[IV] of +1 unit of mf

Stress

Range, before

Permission

Accuracy

0 - 460

1

±3% of IV of +2 unit of mf

Measurement of the resistance of chain (phase- phase, phase - neutral particle)

Range, W

Permission, W

Accuracy

0,01 - 19,99

0,01

±5% of IV of +3 unit of mf

20,0 - 199,9

0,1

* 0,1[m]W in the range 0,0 - 199,9 [m]W (IPM57)

Max. current spikes with the test stress: 127[V] of 3,65[A]
230[V] of 6,64[A]
400 [v] of 11,5[A]
test stress phase- earth 100 - 255[V]/100 - 440[V] with 50[Gts]

The measurement of the resistance of tire (phase - earth)

Range, W

Permission, W

Accuracy

0,01 - 19,99

0,01

±5% of IV of +3 unit of mf

20,0 - 199,9

0,1

200 - 1999

1

* 0,1[m]W in the range 0,0 - 199,9 [m]W (IPM57)

Max. current spikes with the test stress: 127[V] of 3,65[A]
230[V] of 6,64[A]
400 [v] of 11,5[A]
test stress phase- earth 100 - 255[V]/100 - 440[V] with 50[Gts]

The measurement of the resistance of tire without turning off BONDS (phase - earth) Ra of 15[mA]

Range, W

Permission, W

Accuracy

1 1999

1

±5% of IV of +3 unit of mf

Test current 15 mA
test stress phase- earth 100 - 255[V] with 50[Gts]

Measurement of the ground resistance with the add. by the pintles

Range, RE W

Permission, W

Accuracy

0,01 - 19,99

0,01

±5% of IV of +3 unit of mf

20,0 - 199,9

0,1

200 - 1999

1

Test current of <10mA - 77.5 Hz
Stress out of 20[V] RMS


Measurement of the specific conductivity of ground R

Range, R*

Permission

Accuracy

0,60 - 19,99W[m]

0,01 W[m]

±5% of IV of +3 unit of mf

20,0 - 199,9 W[m]

0,1 W[m]

200 - 1999 W[m]

1 W[m]

2,00 - 99,99 [k]W[m]

0,01 [k]W[m]

100,0 - 125,5 [k]W[m]

0,1 [k]W[m]

Measuring circuit is 4 is wire, the carrying of pintles 10 m.
Test current/stress out of 10[mA]-77,5 [Gts]/[do] of 20[V] RMS


Regime of measurement and analysis of the quality of the electric power of the single-phase and 3rd phase networks

Measurement of stress - True RMS

Range, before

Permission, before

Accuracy

The input impedance

15- 310

0.2

±0,5%[IV] of +2 unit of mf

300 [k]W (phase - neutral particle)

310 - 600

0,4

300 [k]W (phase - phase)


Dips and the overvoltage

Range, before

Permission, before

Permission, the time

Accuracy

Accuracy OTN of 50 Hz (time)

The input impedance

15-310

0.2

½ the period

±1,0%[IV]+2 of unit of mf

± 10 ms

300 [k]W (phase - neutral particle)

30-600

0,4

10 ms

300 [k]W (phase - phase)


Measurement of current (with the external tongs)

Range *

Permission, mV

Accuracy

The input impedance

Overload protection

0,005 - 0,26[V]

0,1

±0,5%[IV] of +2 unit of mf

200[k]W

5[V]

0,256 - 1[V]

0,4

* if the range of tongs of 1000[V]/1[V], then tester will measure the current of more than 5[A]

Power measurement of the single-phase and 3rd phase networks

Type of the measurements

Range

Accuracy

Permission

Active

0 - 999,9 W
1 999,9 kW
1 999,9 MW
1000 - 9999 MW

± 1%[IV] + of 2 unit of mf

0,1 W
0,1 kW
0,1 MW
1 MW

Reactive

0 - 999,9 VAR
1 999,9 kilovars
1 999,9 Mvar
1000 - 9999 Mvar

0,1 VAR
0,1 kilovars
0,1 Mvar
1 Mvar

Complete

0 - 999,9 VA
1 999,9 kVA
1 999,9 mVA
1000 - 9999 mVA

0,1 VA
0,1 kVA
0,1 mVA
1 mVA

The active energy

0 - 999,9 VAR
1 999,9 kilovars
1 999,9 Mvar
1000 - 9999 Mvar

0,1 Wh
0,1 [kVtch]
0,1 [MVtch]
1 [MVtch]

Reactive energy

0 - 999,9 [VARch]
1 999,9 [kVARch]
1 999,9 [MVARch]
1000 - 9999 [MVARch]

0,1 [VARch]
0,1 [kVARch]
0,1 [MVARch]
1 [MVARch]

Cos j the measurement of capacity rate

Cos j

Permission

Accuracy, expressed before °

0,20

0,01

0,6

0,50

0,7

0,80

1,0

Harmonics - stress and the current

Range

Base accuracy

Maximum permission

DC - 25H

± 5% + of 2 unit of mf

0,1[V]/of 0,1[A]

26H - 33H

± 10% + of 2 unit of mf

34H - 49H

± 15% + of 2 unit of mf


Measurement of environmental parameters

Range

Accuracy

Permission

Temperature -20… +80°[S]

±2%[IV] + of 2 unit of mf

0,1°[S]

Humidity 0 - 100% OF UR

0.1%UR

Illumination of 0,001[lks] - 20,00 [lks]
0,1[lks] - 2000 [lks]
1[lks] - 20 000 [lks]

0.001 - 0,02 [lks]
0,1 - 2 [lks]
1 20 [lks]

Measurement of the leakage current

Range

Permission

the accuracy

[Vkh].[impedans]

Protection on the overload

0,5 - 999,9 mA

0,1 mA

±5%[IV] + of 4 unit of mf

200[k]W

5[A]


General given

Display matrix 128*128 with the illumination, the size of the screen of 73*73 mm
Internal storage of 999 tests
The operating temperature of 0… 40 °[S], humidity not are more than 80%
Nourishment of 1,5[V] *6 of small batteries type LR6 - AA or the net adapter Of [a]050
Overall sizes/the mass of 225*165*105/1,2 the kgf
Record of the results
- phase and a potential difference
- The current of phase, the current of the neutral particle
- Power - active, reactive, complete
- The active and reactive energies
- Harmonics to 49

Delivery set
- tester,
- collection of 4 wires 1,5 m with 4 “crocodiles” and 2 test wires
- 3 wire cable - the adapter of 3*1 of 300-3000A/1V - HTFLEX3003
- BORSA2050 - case
- 3 wire cable Of shuko - [S]2033
- case with 4 wires even 4 by the pintles
- C2001 - cable for the connection for the sake of the computer and ON TOPLINK
- The management of user down the instrument and the management on [po]
- The guarantee coupon
- The certificate of calibration according to ISO9000

Options
- A0050 - net adapter
- adapter for measuring the impedance with the high resolution - IMP57
- sensor for the level measurement of noise and sound pressure - [NT]55
- SV - 5 portable calibrator for [NT]55
- sensor for measuring of temperature and humidity - [NT]52/05
- sensor for measuring the illumination - [NT]53/05
- shoulder strap for the carrying-over - CN0050
- tongs for measuring the currents of leakage - [NT]96U
- HT98: tongs for the current AC of 1000A/1V Sh of 54mm
- collection of 3 tongs for alternating current of 200-2000[A], 70[mm]-[NR]30[S]2/3
- collection of 3 tongs for alternating current of 3000[A], 70[mm]-[NR]30[S]3/3
- HT903 case based on 3x1-5A/1V for the connection to TA





Current page: Multifunctional tester for measuring the parameters of safety one- and three phase networks SIRIUS 89
Multifunctional tester for measuring the parameters of safety one- and three phase networks SIRIUS 89
Home Sitemap Contact us

Most powerful site:
bílé víno , Betreuerinnen , www.online-auto.co.uk , Otimizaçao de sites , Kitesurfing , pubblicità online