Instrument unites before itself the functions of the multimeter of that making it possible to conduct the measurements of current and voltage, calibrator of equipment and generator, which can manufacture the signals of current and voltage, wide range for checking of electric diagrams, electric brushes and equipment.
- Generation of pulses, the pulse measurements
- Generation of direct current from 0 to ± 25 mA
- Generation of constant stress from 0 to ± 25 [v]
- Function of the measurement of temperature, resistance
- Function of the calibration of thermocouples and temperature sensors
Specification
|
Functions of generator and the accuracy |
Constant stress |
From 0 to ± 2.5 [v], with the permission of 100 μ[V], From 0 to ± 25 [v], with the permission 1 mV, Reduction/the increase: ± 25 [m]A, ± 0.03% of the installation ± of 3 un. of last discharge. |
|
Direct current |
From 0 to ± 25 [m]A, with the permission of 1 μA, Reduction/the increase: ± 25 before, ± 0.03% of the installation ± of 5 un. of last discharge. |
|
Thermoelectric power |
TC (0 °C)/TC (RJ) K: from -176.0 to 1372.0 °C, E: from -220.0 to 839.0 °C, J: from -208.0 to 1108.0 °C, T: from -169.0 to 400.0 °C, R: from -50 [d]o of 100 °C, from 101 to 1769 °C, S: from -50 to 100 °C, from 101 to 1769 °C, B: from 300 to 600 °C, from 601 to 1820 °C, |
|
Accuracy |
± 0.05% of installation ± of 0.5 °C (with the thermoelectric power j) |
|
Measured values the basic accuracy |
Stress: From 0 to ± 2.5 [v], with the permission of 100 μ[V], from 0 to ± 25 [v], with the permission 1 mV, the input resistance: 1 M, ± 0.03% of chg of [velich]. ± 2 [e].[m].[r]. Current: From 0 to ± 25 mA, with the permission of 1 μ[V], the input resistance: 25 Ohm, ± 0.03% of chg of [velich]. ± 2 [e].[m].[r]. Resistance: 100 Ohm, ± 0.2% of chg of [velich]. ± 5 [e].[m].[r]. Temperature: From -25 to 80 °C, with the permission of 0.1 °C Frequency: From 100 Hz to 200 kHz, 5 ranges, ± 0.02% of chg of [velich]. ± 3 [e].[m].[r]. |
|
Display |
[ZHKD], with the illumination, swing. induced number 51000. |
|
Power source |
1.5 [v] AA of alkaline (LR6) of battery × 6, 9420 packings of batteries (Ni- Cd) or 9418-10 ACES is adapters. |
|
Sizes and the mass |
104 mm. altitudes × of 180 mm. latitude × 58 mm. of thicknesses. Mass: 590 deg. (without the batteries) |
|
Accessories |
9168 input cord (1), 9170 verifying probe (1), safety devices (3) |
Options 9184 RJ the sensor 9380 bags for the transfer 9418-10 ACES is the adapters 9420 packings of batteries (Ni- Cd) (7.2 [v]/of 700 [mA]h)