the bodies: (812) 324-56-27, e-mail:
The main thing is the order of catalog the certification of the news To c[tat] by dealer the order of instrument contacts all goods the instruments
1 [u].[e]. = of 1 USD before the rubles on the course TsB RF on the day of payment.    
Search
Basket
Catalog
Multifunctional electrical tester for conducting the measurements of the parameters of electrical networks and equipment MACROTEST 5035

Multifunctional electrical tester for conducting the measurements of the parameters of electrical networks and equipment MACROTEST 5035

MACROTEST 5035 - is this correct selection for checking the safety according to standard EN61010. Because of the microprocessor the instrument ensures the automatic recording of the results of measurements. The built-in interface makes it possible to transmit data for further the processing down the computer or to derive down the press.
MACROTEST 5035 is intended for:

  • testing single-phase electrical chains and equipment
  • checking the integrity of the shielding isolation
  • the measurement BONDS (A- ACE) general and selective type parameters
  • the measurement of the ground resistance on 2, 3 and 4 wire diagrams and conductivity of ground
  • the measurement of insulation resistance with 50/100/250/500/1000[V] of the direct current
  • the measurement of the frequency
  • the measurement of the impedance of short circuit and current loop
  • the measurement of the leakage currents
  • the determination of the order of the alternation of the phases
  • the measurement of voltage and current

Specification

Measurement of the integrity of the shielding wires

Range, Ohm

Permission, Ohm

Accuracy

0,01 - 19,99

0,01

±0,2%[IV] + of 2 unit of mf

20,0 - 99,9

0,1

Test current > of 200 mA, post. for R < of 5[Om], permission 1 mA
Max. the stress of the test of 4[V] of ≤ V0 of ≥ 24 [v]


Measurement of insulation resistance

Test stress, before

Range of measurements, [M]Ω

Permission, [M]Ω

Accuracy

50

0,01 - 19,99

0,01

±2%[IV]+2[ed] of mf, with V/R of >1µ[A]

20,0 - 49,9

0,1

50,0 - 99,9

0,1

±5%[IV]+2[ed] of mf, with V/R of ≤1µ[A]

100

0,01 - 19,99

0,01

±2%[IV]+2[ed] of mf, with V/R of >1µ[A]

20,0 - 99,9

0,1

100,0 - 199,9

0,1

±5%[IV]+2[ed] of mf, with V/R≤1Μ[A]

250

0,01 - 19,99

0,01

±2%[IV]+2[ed] of mf, with V/R of >1µ[A]

20,0 - 199,9

0,1

200 - 249

1

250 - 499

1

±5%[IV]+2[ed] of mf, with V/R of ≤1µ[A]

500

0,01 - 19,99

0,01

±2%[IV]+2[ed] of mf, with V/R of >1µ[A]

20,0 - 199,9

0,1

200 - 449

1

500-999

1

±5%[IV]+2[ed] of mf, with V/R of £1m[A]

1000

0,01 - 19,99

0,01

±2%[IV]+2[ed] of mf, with V/R of >1m[A]

20,0 - 199,9

0,1

200 - 949

1

1000 - 1999

1

±5%[IV]+2[ed] of mf, with V/R of ≤1µ[A]

Max the stress of test 1,3 * the rating
Current [KZ] < of 6,0 mA with 500 [v]
Rating. the current of the test of 500[V]: >2.2 of µA with the load of 230[kOm], east. >1[mA] with 1[kOm] *V[nom].


Checking the tripping time OF THE BONDS

Range, ms

Permission, ms

Accuracy

½ IΔN, IΔN 0 - 999

 

1

 

± 2% of IV + of 2 unit of mf

2 IΔN 0 - 200 general
                0 - 250 [selektivoe]

5 IΔN 0 - 50 general
          0 - 160 selective

Test current 10 mA, 30 mA, 100 mA, 300 mA, 500 mA
Type is BONDS ACE, A general and selective
Stress is phase/earth 100 - 255[V], 50 Hz

Contact voltage Of u[p]

Stress, before

Permission, before

Accuracy

0 - 2 * U[p] (U[p] from 25 [v] to 50 c)

0,1

-0%, + 2%[IV] of +2 unit of mf

Measurement of the impedance of grounding without turning off OF THE BONDS

Range, Ohm

Permission, Ohm

Accuracy IΔN

1 1999

1

-0%, + 5%[IV] of +2 unit of mf

Test current 0,5 IΔN for the test Of u[p], 15[mA] for Ra of 15[mA] test

Checking the differential current of turning off OF THE BONDS

Type OF THE BONDS

Range IΔN, mA

Permission, mA

Accuracy IΔN

With IΔN of ≤10 mA

ACE

(0,5 - 1,4) *I

0,1*I

-0%, + 5% OF IΔN

A

(0,5 - 2,4) *I

0,1*I

-0%, + 5% OF IΔN

With IΔN of >10 mA

 

 

 

ACE

(0,5 - 1,4) *I

0,1*I

-0%, + 5% OF IΔN

A

(0,5 - 2)*I

0,1*I

-0%, + 5% OF IΔN

Frequency (current loop and measurement BY BONDS actively only with 50[Gts])

Range, Hz

Permission, Hz

Accuracy

47,0 - 63,6

0,1

±1%[IV] of +1 unit of mf

Stress (test OF BONDS, loops, the alternations of phases)

Range, before

Permission

Accuracy

0 - 460

1

±3% of IV of +2 unit of mf

Measurement of the resistance of chain (phase- phase, phase - neutral particle)

Range, Ohm

Permission, Ohm

Accuracy

0,01 - 19,99

0,01

±5% of IV of +3 unit of mf

20,0 - 199,9

0,1

Max. current spikes with the test stress:                     100[V] of 3,17[A]
                                                                                                  230[V] of 6,64[A]
                                                                                                  400[V] of 11,5[A]
test stress phase- neutral particle/phase - phase 100 - 255[V] with 50[Gts]

The measurement of the resistance of tire (phase - earth)

Range, Ohm

Permission, Ohm

Accuracy

0,01 - 19,99

0,01


±5% of IV of +2 unit of mf

20,0 - 199,9

0,1

200 - 1999

1

Max. current spikes with the test stress:   100[V] of 3,17[A]
                                                                                230[V] of 6,64[A]
test stress phase- earth 100 - 255[V]/100 - 440[V] with 50[Gts]

The measurement of the resistance of tire without turning off BONDS (phase - earth) Ra of 15[mA]

Range, Ohm

Permission, Ohm

Accuracy

1 1999

1

±5% of IV of +3 unit of mf

Test current 15 mA
test stress phase- earth 100 - 255[V] with 50[Gts]

Measurement of the ground resistance with the add. by the pintles

Range, RE Ohm

Permission, Ohm

Accuracy

0,01 - 19,99

0,01

 

±5% of IV of +3 unit of mf

20,0 - 199,9

0,1

200 - 1999

1

Test current of <10µA - 77.5 Hz
Stress out of 20[V] RMS

Measurement of the specific conductivity of ground R

Range, p *

Permission

Accuracy

0,60 - 19,99[Om]

0,01 Ohm

 

±5% of IV of +3 unit of mf

20,0 - 199,9 Ohm

0,1 Ohm

200 - 1999 Ohm

1 Ohm

2,00 - 99,99 kilohms

0,01 kilohms

100,0 - 125,5 kilohms

0,1 kilohms

Measuring circuit is 4 is wire, the carrying of pintles 10 m. test current/stress out of 10[mA]-77,5 [Gts]/[do] of 20[V] RMS

General given
Display [ZHK] is monochromatic, the size of the screen of 63*63 mm
Internal storage of 365 tests
The operating temperature of 0… 40°[S], humidity not are more than 80%
Nourishment of 1,5[V] *6 of small batteries type LR6 - AA or the net adapter Of [a]050
Overall sizes/the mass of 225*165*105/1,2 the kgf

Delivery set
- the tester
- C2033 3- wire cable is adapter - plug
- KITGE80 collection of 3 cables, 4 “crocodiles” and 2 test wires
- KITTERRNE case with 4 cables “banana - banana” even 4 pintles of the grounding
- EUROLINK2000 [po] on CD -ROm
- C2001 RS232 communication cable
- case for the transfer BORSA2050
- the certificate of calibration according to ISO9000
- the management of the user

Options
- IMP57 device for measuring the impedance with the high resolution
- CN0050 the shoulder strap





Current page: Multifunctional tester MACROTEST 5035
Multifunctional tester MACROTEST 5035
Home Sitemap Contact us

Most powerful site:
Betreuerinnen aus Polen , motorcycle patches , Mini reviews , Used cars , www.moto-page.co.uk , metabolic balance nürnberg