| Gauge of power (wattmeter) 3334 |
Instrument is intended for power measurement, it can be used both before the production and with studies under laboratory conditions, it has high sensitivity and it is capable to measure the very low amount of power.
- Possibility of measuring the stress DC, AC, DC+AC
- Integrated functions for the current and the power
- High accuracy of measurement with error ±0.2%
- Increased period of the guaranteed accuracy of up to 3 years
- The wide range of the measurements of power to 9 kV, stress to 300 [v], current to 30 A, direct introduction,
SPECIFICATION
|
Measured lines |
Single-phase 2- wire |
|
Measured values |
Stress, current, active, total power, capacity rate, frequency, association (current and active power), mapping waveform (current and stress) |
|
Intervals of the measurements |
Stress AC/DC |
to 300 [v] OF RMS |
|
Current AC/DC |
to 30 A RMS |
|
Power |
to 9 kW |
|
Introductory resistance |
2.4 M - stress, 10 m or is more - current (50/60 Hz, by tonic introduction) |
|
Accuracy |
stress, current and the active power (less than 50%) |
current and active power (from 50% to 100% |
|
± 0.1% of [i].[v]. ± 0.2% [p].[sh]. (DC) |
|
±0.1% of [i].[v]. ± 0.1% [p].[sh]. (45[Gts] - 66[Gts]) |
±0.2% of [i].[v]. (45[Gts] - 66[Gts]) |
|
±0.1% of [i].[v]. ± 0.2% [p].[sh]. (66[Gts] - 1[kGts]) |
±0.3% of [i].[v]. (66[Gts] - 1[kGts]) |
|
±3% of [i].[v]. (1[kGts] - 5[kGts]) |
±3% of [i].[v]. (1[kGts] - 5[kGts]) |
|
Frequency characteristic |
From 45 Hz to 5 kHz |
|
Form of fluctuations against the output |
Image of the leading-out parameters: stress, current and active power (3 channels simultaneously) |
|
Analog output |
Image of the leading-out parameters: stress, current and active power and the selection of each parameter separately (4 channels simultaneously) |
|
Other functions |
RS-232C interface, the function Of true RMS, average [arefmiticheskoe] value DC, the retention of maximum value, the relationship of the parameters of installation VT or CT, the averaging of value. |
|
Period of [vyborki] |
5 times per second |
|
Power source |
From 100 to 240 [v] AC, 50/60 Hz. |
|
Sizes and the mass |
100 mm altitudes × of 210 mm latitude × 245 mm of thicknesses. Mass: 2.5 kg. |
|
Accessories |
Power cord (1), operating instructions (1). |
Options: 9151-02 GP-IB coupling cable (2 m) 9151-04 GP-IB coupling cable (4 m) 9637 RS-232C coupling cable (9 contacts (pin) - 9 contacts (pin) of 1.8 m) 9638 RS-232C coupling cable (9 contacts (pin) - 25 contacts (pin) of 1.8 m) 9266-01 leading-out cable for power measurement 9442 printers 9443-02 ACES is adapters (for printer 9442, eu), 9443-03 (USA) 9444 coupling cable (for printer 9442) 1196 paper for the press (25 m, 10 cylinders, for 9442)
Current page: