Instrument carries out the comprehensive estimation of power, speed of rotation, torque of 3- phase inverter engines, so it is converter efficiency harmonics. It can measure the carrier frequencies of the secondary circuit of inverter engines. The synchronization of analysis with the rotation of engine also is allowed.
Specification
|
Measured lines |
Single-phase 2- wire, single-phase 3- wire, three-phase 3- wire, three-phase 4- wire, (it depends on the utilized options). |
|
Measured values |
With the use of options 9600, 9601, 9602: Stress, current, the peak value of relationship stress/current. Effective, reactive, total power, capacity rate, phase, frequency. Integrated value of current, power, nominal load, efficiency of harmonic (to 3000 degrees), waveform.
With the use of option 9603-01 (with the sensor of torque): Stress, the torque, the RPM- number of revolutions per minute, frequency, the power of engine. |
|
Intervals of the measurements |
Stress: from 6.0000 [v] to 1.0000 kV (it depends on options)
Current: from 200.00 mA to 500.00 A (it depends on options)
Power: It depends on the combination of the range of stress and current. |
|
Range of the integration |
From 0 to ±999999 Of [tA]h/TWh, (time of integration to 10000 hours). |
|
Accuracy |
With use as far as one of the option 9600, 9601, 9602: ± 0.1% of measuring. value ± 0.1% of entire scale (stress, current, power, with the frequency from 45 [d]o 66 Hz). |
|
Frequency |
With option 9600: DC, 0.5 Hz to 1 M[Gts]. With the option the 9601:5 Hz of [d]o of 100 k[Gts]. With option 9602: DC, 0.5 Hz of [d]o of 200 k[Gts] (it depends o[t] of the accuracy of tongs). |
|
Output signal |
Analog level: Stress, current, active power, 5 [v] DC of the entire scale.
Monitor of the timetable of the signal: Stress, current, 1 [v] of rms of the entire scale.
D/The output: Are derived 8 arbitrarily selected parameters, ±5 in DC of the entire scale. |
|
Other functions |
6.4 inches TFT liquid-crystal display, RMS/MEAN rectification, FDD, GP-IB/RS-232C interface, scaling, averaging. |
|
Power source |
100/120/200/230 [v] AC (it is switched automatically), 50/60 Hz. |
|
Sizes and the mass |
150 mm altitudes × of 430 mm latitude × 370 mm of thicknesses. Mass: 15 kg. |
|
Accessories |
Power cord, connector. | Information for the order Measurements cannot be conducted by means of only MEASURING DEVICE OF THE ENGINE/OF HARMONIC COMPONENTS 3194. It is necessary to acquire the firm optional input module (it is possible to select as far as 9600, 9601, 9602)
Observations on the selection of the input module
- Use for each measuring line one and the same input module
- You will establish modules before the sequence, beginning based on channel 1
- For models 9603 or 9603-01 it is possible to establish only one module.
- When model 9602 is selected, use optional sensor with the [tokopreobrazuyushchimi] tongs.
The options, which can be established at the plant (you will determine with the order) 9600 AC/DC THE MODULUS OF THE DIRECT INTRODUCTION 9601 AC THE MODULUS OF THE DIRECT INTRODUCTION 9602 AC/DC INPUT MODULE WITH THE [TOKOPREOBRAZUYUSHCHIMI] TONGS 9603-01 MODULI OF INPUT OF EXTERNAL SIGNAL (only 3194) 9604 MODULES OF THE PRINTER
Options * 9270 SENSORS with THE [TOKOPREOBRAZUYUSHCHIMI] TONGS (20[A] ACE) * 9271 SENSORS with THE [TOKOPREOBRAZUYUSHCHIMI] TONGS (200[A] ACE) * 9272 SENSORS with THE [TOKOPREOBRAZUYUSHCHIMI] TONGS (20/200[A] ACE) 9277 UNIVERSAL T with THE [TOKOPREOBRAZUYUSHCHIMI] TONGS (20[A] [AS]/DC) 9278 UNIVERSAL T with THE [TOKOPREOBRAZUYUSHCHIMI] TONGS (200[A] [AS]/DC) * 9279 UNIVERSAL T with THE [TOKOPREOBRAZUYUSHCHIMI] TONGS (500[A] [AS]/DC) * 9290-10 ADAPTER with THE [TOKOPREOBRAZUYUSHCHIMI] TONGS (1500[A] ACE) 9232 PAPERS FOR THE PRESS (10 m, 1 cylinder, for 9604)
* marking [SE] is absent
Current page:
Gauge of power 3194 |