The operating conditions
- Current (automatic ranking)
- VKh. Stress 30- 600 [v]
- Supply voltage by 60- 600 [v]
- Frequency 45 - 65 Hz
- Phase 0 - 360° or -180° of +180°
- Capacity rate -1 - +1
- Temperature -20 ° +70 °
- Humidity 0 - 95%
Physical characteristics of the instrument
- Detachable on the counter or portable
- Weight of 7,2 kgf (12,6[kg] of [transp])
- Sizes of 127 X of 444,5 X of 158,75 mm
- [ZHK] sensory screen with the illumination
Checking and the calibration
- It does not require manual tuning, calibration is produced with the aid of software
- [Mezhkalibrovochnyy] interval of 365 days
- Readiness 15 flogged after the switching on
Accuracy
The maximum permissible error is manifested with [summarnomvliyanii] of all destabilizing factors and when [s]osφ < 0,5.
Example of the selection of the instrument
For example, let us select instrument RD-31-334. This will mean that the instrument is capable to measure the following values: Watt-hours (Whrs), stress (the V), current (a), Pitch- hours (VARhrs), Volt-ampere- hours (VAhrs), reactive hours (Qhrs), watts (W), pitches, total power (VA), Volt- hours (Vhrs), ampere-hours (Ahrs), volts ² - hours, amperes ² - hours, phase angle, capacity rate, frequency, the fixation of min[i] of max[znacheniy] of all enumerated values.
Instrument has functions of comparator and harmonic analyzer, entrances with the range of current 200 A, and it is portable. |
Menu for the selection of the model Last three numbers determine the model of counter. First number - set of the measured parameters. The second - presence of comparator, harmonic analyzer and/or analog entrance. The third - configuration of current entrance.
Interpretation of the code of the model RD-3X-2xx
Watt-hours (Whrs), stress (the V), current (a), Pitch- hours (VARhrs), Volt-ampere- hours (VAhrs), reactive hours (Qhrs), watts (W), pitches, total power (VA), phase angle, capacity rate, frequency.
RD-3X-3xx
Watt-hours (Whrs), stress (the V), current (a), Pitch- hours (VARhrs), Volt-ampere- hours (VAhrs), reactive hours (Qhrs), watts (W), pitches, total power (VA), Volt- hours (Vhrs), ampere-hours (Ahrs), [Volt]2- hours, [Amper]2- hours, phase angle, capacity rate, frequency, the fixation of min[i] of max[znacheniy] of all enumerated values.
RD-3X-4xx
Watt-hours (Whrs), stress (the V), current (a), Pitch- hours (VARhrs), Volt-ampere- hours (VAhrs), reactive hours (Qhrs), watts (W), pitches, total power (VA), Volt- hours (Vhrs), ampere-hours (Ahrs), volts ² - hours, amperes ² - hours, phase angle, capacity rate, frequency, the fixation of min[i] of max[znacheniy] of all enumerated values, the indication of average values.
RD-3X-[kh]0x - without comparator and harmonic analyzer RD-3X-x1x- with the built-in comparator. RD-3X-x2x- with the harmonic analyzer. RD-3X-x3x- by c[komparatorom] and by harmonic analyzer RD-3X-x4x- analog entrance (for U, A, P, Q, VA) (2 mADCmax) RD-3X-x5x- comparator and the analog entrance RD-3X-x6x- analyzer is [garmonikanalogovyy] entrance. RD-3X-x7x- comparator, the analysis of harmonics the analog entrance RD-3X-xx1- 120 A entrances, fastening on the counter RD-3X-xx2- 200 A entrances, fastening on the counter RD-3X-xx3- 120 A entrances, portable RD-3X-xx4- 200 A entrances, portable |